The purpose of the product TL Booster is to perform Vehicle Queue Management smoothly. It is designed to use at Toll Plazas for vehicle detection, tailgating vehicle separation and to identify vehicle directions in order to perform toll operation quickly and seamlessly. The TL Booster incorporates Laser Technology and is intended to handle high speed vehicle traffic. It also helps to reduce installation and maintenance overheads.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | KENT/TLBSTR/V1.0 |
3 | Architecture | 32-bit ARM Processor |
4 | Technology | Laser, Time of flight measurement |
5 | Laser Class | Class 1 |
6 | Operating Range | > 5 meters |
7 | Angular Resolution | 0.23° |
8 | Communication Interface | Ethernet |
9 | Operating Voltage | DC24V |
10 | Inputs/Outputs | Opto-Isolated digital input/ Potential free contact output |
11 | Relative humidity | < =90% |
12 | Protection | Protection against overcurrent/short circuit |
13 | Operating Temperature | -20°C to 60°C |
14 | MTBF | 5 million cycles |
15 | Reliability |
MBTF: 50,000 hours MTTR: 0.20 hrs |
16 |
The AVCC system will be able to count and distinguish between predefined classes of vehicle. This
information will be transmitted to the Lane Computer and simultaneously to the LSDU (Lane Status Display Unit) data system on completion of AVCC classification.
The AVC Processor analyzes the Pattern/ Profile of vehicle, as listed below, for the classification.
No |
Descriptions |
Remarks |
1 | Technology | Laser scanner, time-of-flight measurement |
2 | Measurement range | max 65 m 10 m @ 2% remission factor, 30 m @ 10% remission factor |
3 | Number of planes | 1 |
4 | Number of points/planes | max. 274* |
5 | Angular resolution | max. 0.3516 °* |
6 | Angular coverage | > max. 96 °* |
7 | Rotating speed | 900 turns/min |
8 | Scanning frequency | 60 Hz |
9 | Remission factor | > 2 % |
10 | Laser emission characteristics | wavelength 905 nm; max. output pulse power 75 W (CLASS 1) wavelength 650 nm; max. output CW power 3 mW (CLASS 3R) |
11 | Supply voltage | 10-35 V DC @ sensor side |
12 | Power consumption | < 5 W |
13 | Peak current at power-on | 1.8 A (max. 80 ms @ 35 V) |
14 | Serial communication Type Interface Communication mode Transmission speed Topology Symbol coding File type | see AN LZR®-U920/-U921 Protocol (available for download on our website) asynchronous RS 485 half-duplex 460800 bit/sec (max: 921600 bit/sec) point to point 1 start bit, 1stop bit, no parity bit 8 bits |
15 | Cable length | +/- 150 mm |
16 | Connector | M12 male, 8 poles |
17 | Input Max. contact voltage Voltage threshold | 1 optocoupler (galvanic isolated - polarity free) 30 V DC (over-voltage protected) Log. H: >8 V DC; Log. L: <3 V DC |
18 | LED-signal | 2 bi-coloured LEDs: function status; 1 blue LED: power-on status; 1 orange LED: error status |
19 | Dimensions | 125 mm (D) x 93 mm (W) x 76 mm (H) |
20 | Material | PC/ASA |
21 | Colour | black |
22 | Protection degree | IP65 |
23 | Temperature range | -30 °C to +60 °C if powered; -10 °C to +60 °C unpowered |
24 | Humidity | 0-95 % non-condensing |
25 | Vibrations | < 2 G |
26 | Pollution on front screens | max. 30 %; homogenous |
27 | Expected lifetime | 20 years |
28 | Norm conformity | 2006/95/EC: LVD; 2011/65/EU: RoHS 2; 2004/108/EC: EMC EN 60529:2001; IEC 60825-1:2007 Laser Class 1&3R; EN 60950-1:2005 EN 61000-6-2:2005 EMC - Industrial level EN 61000-6-3:2006 EMC - Commercial level |
The Automatic Lane Barrier (ALB) is used to allow only authorized vehicles to pass through the lane. A torque motor powers the barrier for raising and lowering the boom. The motor can be blocked at any position without causing any damage. In the event of Power failure, the boom is automatically raised. The boom weight is exactly balanced by Built-in springs.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | Kent/GB 02-11 |
3 | Barrier width max | 3m |
4 | Opening/ closing time | 1 Sec |
5 | Power consumption max | 100 w |
6 | On-time | 100% |
7 | Supply voltage | Wide voltage range 220/110V±10% |
8 | Frequency | 50-60 Hz |
9 | Electric cabinet working temperature | -40°C to +75°C |
10 | Mechanical core working temperature | -35°C to +85°C |
11 | Relative humidity | < =90% |
12 | Housing dimensions (H x W x D) | 950x330x280 mm |
13 | Weight | 65kg |
14 | MTBF | 5 million cycles |
15 | Ingress protection | IP 54 |
16 | Constant speed / time under variable wind speeds | Yes |
17 | Smooth Landing of Boom arm without swaying | Yes |
18 | Certification | CE – EN Certified |
The Fog Light (FL) is located on the bull nose (Crash Barrier) in a position where it is readily visible to users of the toll road. The fog light shall consist of an inner amber core and an outer white ring. The amber LEDs shall always be glowing; whereas the white LEDs shall be flashing at a specified frequency.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | KENT/FL/V1.0 |
3 | Aspect Diameter | 200 mm Φ |
4 | Display(Inner Core) | 1White LED, 5 Rings |
5 | Display(Outer Ring) | Amber LED, 2 Rings |
6 | LED | 5mm in diameter, 8000 MCD |
7 | Frequency | 20-30 cycles / min. shall be adjustable using a potentiometer or other suitable means of adjustment |
8 | Duty Cycle | 66.67 % |
9 | Visibility Range | 100 m (under extreme foggy conditions) |
10 | Viewing angle | 20 degree from central axis in either sides |
11 | Enclosure | Polycarbonate |
12 | Working Voltage | 220 Volts ac ± 20 |
13 | MTBF | 100,000 hrs |
14 | MTTR | 00.30 hrs |
Handheld Device is used to generateToll tickets at the plaza. Handheld device is very useful at the plaza to clear the queues during the rush hours. The device is integrated with the Toll Management System and is able to generate the barcoded receipts
No |
Item |
Specifications |
1 | Make | KENT ITS |
2 | Model | KENT/HDR/V1.0 |
3 | Processor | 32 Bit ARM 7 Controller |
4 | Storage Capacity | 10,000 Records |
5 | Clock | Inbuilt RTC |
6 | Display | High Clarity 20 x 4 character Display |
7 | Security | 3 DES Password Protection |
8 | Communication | RS232/RS485/Ethernet/wireless |
9 | Output | 2” Thermal Printer with Cutter, capable of printing Barcode. |
10 | Environmental Conditions | Operating Temp : 0°C to 55°C Humidity : 5% to 90% |
11 | Dimensions (mm) | L- 300 x W - 100 x D- 50 |
12 | MTBF | 1 Mil Transactions |
13 | MTTR | 1 Hr |
Manual Booth Controller is a device used in emergency conditions to bypass the system and controlling the various hardware equipments on a single key. This is helpful while using closed lanes in case of peak traffic flows.
No |
Item |
Specifications |
1 | Brand | KENT ITS |
2 | Model | KENT/MBC/V1.0 |
3 | Technology | Manual Booth Switches |
4 | Dimension | 150x70x50mm |
5 | Material and color | Polycarbonate white cover and black housing |
6 | Interface | Solid State Relay board |
7 | Weight | < 1 Kg |
8 | Operating Voltage | 24VDC |
9 | Power Consumption | NIL |
10 | Installation | Screw Arrangement at the bottom |
11 | Environment Conditions | Operating Temp : -25°C to 70°C |
12 | Selector Switch Reliability | More than 1Million operations |
13 | Protection | IP65 |
KENT Toll Lane Controller (TLC) is specially designed to satisfy the specific requirements of toll automation and to face problems such as harsh and dusty environment, space constraint in the toll booth etc.
The KENT TLC comprises of AVC Board, Relay Board, Lane PC, MD etc. All these components in one unit is quite useful in prohibiting malpractices on the lane and ensuring space availability in the toll booth.
No |
Item |
Specifications |
1 | Make | KENT ITS |
2 | Model | KENT/TLC/V1.0 |
3 | Dimensions | 800mm (H) x 800mm (W) x 210mm (D) |
4 | Weight | 32 KG |
5 | Installation and Fixing Details | Wall and Floor Mount Options |
6 | Cables |
Power cable : 0.75mm gauge Power cable Data cable : 3 core, 6 core& 10 core cables will be used to control lane equipments. All cables with proper termination and identification. |
7 | Materials | Mild steel with powder coating / Stainless steel |
8 | Color | Grey |
9 | Power Supply Requirements | 220-270VAc /50-60Hz |
10 | Access For Maintenance Modularity of Construction | Front side Door Access for Maintenance |
11 | Design Criteria |
Architecture: • 32 Bit ARM 7 Architecture I/O Ports: • 32Opto-Isolated Input Terminals • 8 Solid State Relay Output Terminals Protection level: • Circuit Breaker • Fuse Protection for Over Current • Metal Oxide for Over Voltage Surge Protection • Short Circuit Protection |
12 | Environment Conditions |
Operating Temp : 0°C to 60°C Humidity : 0% to 90% |
13 | Certification | CE – EN Certified |
The Over Head Lane Signal or Over Head Traffic Light is used to signal out the road users whether the lane is in operating mode or not. The Green light indicates the lane as Open while the Red light indicates the lane as Close. The KENT Over Head Lane Signals are designed using LED technology and comes with built in dimmer facility to minimize the power consumption at night at the toll plaza.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | Kent/OTL_V1.1 |
3 | Technology | LED |
4 | Dimension | 800mm x 400mm x 350mm |
5 | Material and finishes | Polypropylene /Polycarbonate / Mild Steel with black color powder coated with Sun visor |
6 | Aspect diameter | 300mm |
7 | Aspect Color | RED and Pure Green |
8 | Interface | Directly 230V/Ac switching from potential free devices |
9 | Visibility | >300mtrs |
10 | Cables | Power Cable |
11 | LED Type |
Super Bright Day visible 12000 - 16000 mcd at 20 mA, 45˚ viewing angle for RED 21000 - 24000 mcd at 20 mA, 45˚ viewing angle for GREEN |
13 | Weight | < 8 Kg |
14 | Operating Voltage | 220-270VAc /50-60 Hz |
15 | Power Consumption | 18W max at 25˚C |
16 | Installation | Bolting Arrangement to the canopy |
17 | Environment Conditions |
Operating Temp : -10°C to 60°C Humidity : 0 to 90% |
18 | Reliability |
MTBF : 50,000 hours MTTR : 0.40 hrs |
19 | Access For maintenance | Front Door Access for Easy Maintenance |
20 | Protection | IP 65 |
21 | Certification | CE – EN Certified |
The Smart Card Reader is used to process, read and write to the contact less Smart Card. The distance to which the Smart Card Reader can access the Smart Card is approximately 80 mm.
The Smart Card Reader is with processor which ensures least reading time, greater security and added features as per the Toll operator's need.
No |
Item |
Specifications |
1 | Make | KENT ITS |
2 | Model | KENT/RFR/V1.4 |
3 | Type | ISO 14443 A Type Reader/Writer |
4 | Read/write distance | Up to 80mm |
5 | Read/write time | < 100 msec. |
6 | Data transmission speed | 106 Kbits/sec |
7 | Interface protocol | Proprietary |
8 | Security | DES |
9 | Installation and Fixing Details | Table top or Wall mount |
10 | Cables |
Power cable RS232 cable / USB Cable Antenne cable: RG174 AU, 50 ohm |
11 | Material and finishes | Polypropylene |
12 | Color | Black |
13 | Power Supply Requirement | 5V, 200 ma max |
14 | Access for maintenance, modularity of construction | Modular design |
15 | Operating Temperature | 0°C to 55°C |
16 | Relative Humidity | 10 % to 90 % |
17 | Reliability and maintainability |
MTBF: 30,000 hrs MTTR: 0.20 hrs |
A metal detector is an electronic instrument which detects the presence of vehicle when in close proximity with electromagnetic field of loop. The metal detector comes with configurable loop frequency & metal detection sensitivity. Also indication for metal detection and loop wire break condition are present.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | KENT/MD/V1.1 |
3 | Label Protocol |
30Khz to 120Khz (DIP switch for frequency selection) |
4 | Interface | Inductive Ground Loop |
5 | Response Time | <50ms |
6 | Sensitivity | 10 Sensitivity Levels |
7 | Visual Indication |
Red Led POWER Green Led - DETECT Yellow Led LOOP ERROR |
8 | Presence Relay | Change over relay DC24V/1A |
9 | Reset | Reset with reset switch on faceplate |
10 | Power Supply | DC 24V/0.5A |
11 | Operating temperature | -20 to 60° degree Celsius |
12 | Dimensions (H x W x D) mm | 90x80x50mm |
13 | Protection | IP 54 |
14 | Reliability and maintainability |
MTBF: 30,000 hours MTTR: 0.15 hour |
The Traffic Light (TL) is used to instruct vehicles to stop or pass through the lane. The TL is Red when the Toll Collector is expecting the vehicle at the booth. After the transaction is done; the TL turns Green to instruct the vehicle to pass through the lane.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | Kent/TL_V1.1 |
3 | Technology | LED |
4 | Dimension | 280mm x 560mm x 350mm |
5 | Material and finishes | Polycarbonate / Polypropylene with Sun visor |
6 | Aspect diameter | 200mm |
7 | Aspect Color | Red and Pure Green |
8 | Interface | Directly 230V/Ac switching from potential free devices |
9 | Visibility | >20mtrs |
10 | Cables | Power Cable |
11 | LED Type |
Super Bright Day visible 8000 - 10000 mcd at 20 mA, 45˚ viewing angle for Red 8000 - 10000 mcd at 20 mA, 45˚ viewing angle for Green |
12 | Weight | < 6 Kg |
13 | Operating Voltage | 220-270VAc /50-60 Hz |
14 | Power Consumption | 10W max |
15 | Installation | Bolting Arrangement to the Pole |
16 | Environment Conditions | Operating Temp : -20°C to +60°C Humidity : 0 to 90% |
17 | Reliability |
MTBF: 50,000 hours MTTR: 0.20 hrs |
18 | Access For maintenance | Front Door Access for Easy Maintenance |
19 | Protection | IP 65 |
20 | Certification | CE – EN Certified |
The User Fare Display is a component in the Electronic Toll Collection System located at the Toll Booth. This 2-line by 13-character LED type message display is optimized for use as a User Fare Indicator or as part of a lane driver feedback system.
No |
Descriptions |
Remarks |
1 | Make | KENT ITS |
2 | Model | KENT/UFD/V1.4 |
3 | Processor | 32 bit ARM7 |
4 | Interface | RS232/RS485/Ethernet |
5 | Capacity | 2 lines; 13 characters on each line |
6 | Character Dimension | 60 x 40 mm formed by 5 mm LED |
7 | LED Pixel Pitch | 10mm |
8 | LED Luminous Intensity | >2000 MCD |
9 | Power Supply Requirement | 240Vac; 25W |
10 | Weight | Approximately 8.0 kg |
11 | Température | 00C to +550C |
12 | Material and Finishes | Mild Steel with black color powder coated |
13 | Type of Protection | IP65 |
14 | Overall Dimension (mm) | 730mm(W) x 230mm(H) x75mm(D) |
15 | Reliability | MTBF : 30,000 Hrs MTTR : 0.20Hr |
16 | Certification | CE – EN Certified |
12/3B, Siddharth Tower, Office No. 1003, 10th Floor, Kothrud, Pune-411 029, (MS), India.
+91 9604699000
info@kent-india.com